Loading...
Good Site
products navigation  
Home   |   About us   |    Products   |   Main Market   |   Contact us
     Clients Login
Username
Password
Validte  
       
My Cart     Forgot Password?
    Service Contact
  Email: sales@fiberer.com
  MSN: contact kevinhenyi99@hotmail.com
  Tel: +86-755-2191-0661
  Fax: +86-755-3322-9601
      
Indoor Fiber Cables
Name:

Indoor Fiber Cables

Class:
Fiber Cables
Type:
Indoor Fiber Cables

Indoor Cables can be successfully used for pach cord / connector / jumper fiber with 9/125¦Ìm Fiber,50/125¦Ìm Fiber,62.5/125¦Ìm Fiber,100/140¦Ìm Fiber,Single Fiber,Multimode Fiber.

Optical Fiber Cable Workshop Pictures:

  

Simplex Cables


Tight buffer fiber strengthened by aramid yarn with a flexible outer jacket.
Features
¡õ   ¦µ900um or ¦µ600um tight buffer fiber, semi-tight buffer fiber also available.
¡õ   Nominal outer jacket diameter from 2.0mm to 2.9mm.
¡õ   PVC or Low Smoke Zero Halogen (LSZH) is available as jacket material.
¡õ   Color coding complied with TIA/EIA-598-B.
Applications
¡õ   Ideal for direct terminated with various types of connectors.
¡õ   Rugged construction for indoor installations.
Mechanical Specifications
Item No. Diameter
(mm)
 weight
(kg/km)
Maximum Tensile
Load(N)
Minimum Bend
Radius
(mm)
Operating
Temperature
(¡æ)
Installing Operating
A1-B1.1-ZV-29 2.9 8 200 100 30 -20~+60
A1-B1.1-ZY-24 2.4 4.5 80 40 24 -20~+60
A1-B1.1-ZV-20 2.0 4.5 80 40 20 -20~+60
¡¡
Duplex Cables


¡¡

Figure 8 Zip cord construction consists of 2 single-fiber cable.
Features
¡õ   ¦µ900um or ¦µ600um tight buffer fiber, semi-tight buffer fiber also available.
¡õ   Nominal outer jacket diameter from 2.0mm to 2.9mm.
¡õ   PVC or Low Smoke Zero Halogen (LSZH) is available as jacket material.
¡õ   Color coding complied with TIA/EIA-598-B.
Applications
¡õ   Ideal for direct terminated with various types of connectors.
¡õ   Rugged construction for indoor installations.
Mechanical Specifications
Item No. Diameter
(mm)
 weight
(kg/km)
Maximum Tensile Minimum Bend
Radius
(mm)
Operating
Temperature
(¡æ)
Installing Operating
A1-B1a-ZY-28 2.8¡Á5.7 16 400 200 30 -20~+60
A1-B1a-ZY-28 2.0¡Á4.1 9 150 80 30 -20~+60
A1-B1a-ZY-28 1.8¡Á3.7 7.5 150 80 30 -20~+60
A1-B1a-ZY-28 1.6¡Á3.3 6 150 80 30 -20~+60
Tight Buffer, Semi-light Buffer Fiber


Optical fiber with tight buffer, or semi-tight buffer.
Features
¡õ   Tight buffer fiber in ¦µ900 um or ¦µ600um outer diameter or semi-tight bight buffer fiber in ¦µ900um
       outer diameter.
¡õ   Polyester elastomer, LSZH, PVC, modified Polypropylene or Nylon-12 are available as buffer material.
¡õ   Semi-tight buffer fiber can be easily stripped off 1 meter long.
¡õ   Color coding complied with TIA/EIA-598-B.
Applications
¡õ   For use of producing various types premises fiber optic cable.
¡õ   Can be terminated with standard connectors.
¡õ   Specialized tight buffer fiber is ideal for fiber sensor systems.
Mechanical Specifications
Item No. Diameter
(mm)
 weight
(kg/km)
Maximum Tensile
Load(N)
Minimum Bend
Radius
(mm)
Operating
Temperature
(¡æ)
Installing Operating
T-B1.1-ZV-06 0.6 0.4 4 1.5 30 -20~+60
T-B1.1-H-09 0.9 0.9 6 3 30 -45~+85
T-B1.1-ZY-09 0.9 0.9 6 3 30 -20~+60
T-B1.1-N-09 0.9 0.9 6 3 30 -45~+85
Strengthened Tight Buffer Fiber


Optical fiber surrounded by aramid strength member, and a PVC tight buffer.
Features and Applications
¡õ   Enhanced tensile strength by aramid surrounding bare fiber.
¡õ   PVC tight buffer in ¦µ900um outer diameter.
¡õ   Color coding complied with TIA/EIA-598-B.
¡õ   Ideal for use in optical device, equipment which requires high tensile performance.
Mechanical Specifications
Item No. Diameter
(mm)
 weight
(kg/km)
Maximum Tensile Minimum Bend
Radius
(mm)
Operating
Temperature
(¡æ)
Installing Operating
TE-B1.1-ZV-09 0.9 0.9 10 5 30 -20~+60
¡¡
Fiber Protecting Tube


Features and Applications
¡õ   ¦µ900um tube can use PVC, modified PP, polyester elastomer materials.
¡õ   Also available ¦µ900um tube surrounding by aramid yarn and ¦µ2.9mm or ¦µ2.0mm jacket.
¡õ   Color coding complied with TIA/EIA-598-B
¡õ   For use in optical communication apparatus, equipment, to protect bare fiber.
Mechanical Specifications
Item No. Diameter
(mm)
Tube Material Heat Shrink Rate Operating Temperature(¡æ)
H-P-09 0.9 MPP 2.5% -40~+70
H-H-09 0.9 Elastomer 2.5% -40~+85
H-H-09-ZY-20 2.0 LSZH jacket, elastomer tube 2.5% -20~+60
H-P-09-ZV-29 2.9 PVC jacket, MPP tube 2.5% -20~+60

Distribution Cables


Distribution cable consists up to 12 tight buffer fiber strengthened by aramid yarn, and protected by an outer jacket.
Features
¡õ   Small form factor, high performance with lower cost.
¡õ   ¦µ900um tight buffer fiber, semi-tight buffer fiber also available.
¡õ   SZ stranded cable core for better transmission performance.
¡õ   PVC or Low Smoke Zero Halogen (LSZH) is available as jacket material.
¡õ   Color coding complied with TIA/EIA-598-B.
Applications
¡õ   Ideal for installation in indoor, LAN, and distribution networks.
¡õ   Can be terminated with various types of connectors.
Mechanical Specifications
Item No. Diameter
(mm)
 weight
(kg/km)
Maximum Tensile
Load(N)
Minimum Bend Radius
(mm)
Installing Operating Installing Operating
2 4.2 24 400 130 10 Times of Outer Diameter 15 Times of Outer Diameter
4 4.2 24 400 130
6 4.8 30 450 150
8 5.4 40 500 170
12 6.0 45 600 200
 
Sensing Cables


Elastomer tight buffer fiber strengthened by aramid yarn with a flexible elastomer outer jacket.
Features
¡õ   ¦µ900um elastomer tight buffer fiber, and elastomer outer jacket for a wide range temperature
       applications.
¡õ   Polyester elastomer, polyurethane or Low Smoke Zero Halogen (LSZH) is also available as jacket
       material.
¡õ   Color coding complied with TIA/EIA-598-B
Applications
¡õ   Ideal for fiber optic sensor network for detecting temperature and strain.
¡õ   Compatible with various standard connectors.
¡õ   Rugged construction for wide range temperature indoor installation.
Mechanical Specifications
Item No. Diameter
(mm)
 weight
(kg/km)
Maximum Tensile Minimum Bend
Radius
(mm)
Operating
Temperature
(¡æ)
Installing Operating Installing Operating
A1-B1.1-H-20 2.0 4.5 80 40 30 -55~+125 -45~+85
A1-B1.1-ZU-29 2.9 8 200 100 30 -20~+60
Ribbon Cables

Standard color coded ribbon fiber strengthened by aramid yarn protected by a flexible outer jeacket.
Features
¡õ   Up to 12 fiber count.
¡õ   Small form factor, high density.
¡õ   PVC or Low Smoke Zero Halogen (LSZH) is available as jacket material.
¡õ   Ribbon fiber color coding complied with TIA/EIA-598-B
Applications
¡õ   Ideal for terminated with MT and MTP connectors
¡õ   For indoor installations.
Mechanical Specifications
Fiber Count Dimension
(Height X Width, mm)
 weight
(kg/km)
Maximum Tensile
Load(N)
Minimum Bend
Radius
(mm)
Operating
Temperature
(¡æ)
Installing Operating Installing Operating
4 1.8¡Á3.5 8 200 100 10 Times of Height 15 Times of Height -20~+60
6 1.8¡Á3.5 8
8 2.0¡Á4.0 9
12 2.2¡Á4.5 10

Download Indoor Fiber Cables Specification¡¡

** You can click 'getOffer' or 'AddToCart' button to get the formal offer document directly.
** If you are agent / OEM / middle trade, please copy the specification into word document from our website ,then send it to your clients.
 
If not vote,please vote,thanks!
What do you think of fiberer?
Price is good and competitive.
Price need to be lower.
Order is convenient on website.
Order is slow and not convenient on website.
Fiberer is trusty.
I need to know more from profile.

  
Print   |    Add in favorite

Indoor Fiber Cables,Tight Buffer,light Buffer Fiber,Sensing Cables,Simplex Cables

sales@fiberer.com
Professional Fiber Optic Equipment
Fiberer Global Tech Ltd. Copyright© 2010